Common Vulnerabilities and Exposures (CVE) is a critical tool for maintaining software security, providing a standardized way to track and manage vulnerabilities across systems. Organizations should regularly monitor CVE databases, assess the impact of vulnerabilities, and apply patches promptly to reduce the risk of exploitation.
CVE (Common Vulnerabilities and Exposures) is a public database that provides a standardized method for identifying, tracking, and referencing publicly disclosed security vulnerabilities in software and hardware.
Each vulnerability receives a unique identifier called a CVE ID (e.g., CVE-2023-12345), making it easier to reference specific vulnerabilities across different tools and databases.
Total Search Results: 158437
CVE ID | Description | Severity | Published Date | Affected Vendor | Action |
---|---|---|---|---|---|
CVE-2021-27320 | Blind SQL injection in contactus.php in Doctor Appointment System 1.0 allows an unauthenticated attacker to insert malicious SQL queries via firstname parameter. | Unknown | N/A | n/a | |
CVE-2021-27328 | Yeastar NeoGate TG400 91.3.0.3 devices are affected by Directory Traversal. An authenticated user can decrypt firmware and can read sensitive information, such as a password or decryption key. | Unknown | N/A | n/a | |
CVE-2021-27329 | Friendica 2021.01 allows SSRF via parse_url?binurl= for DNS lookups or HTTP requests to arbitrary domain names. | Unknown | N/A | n/a | |
CVE-2021-27330 | Triconsole Datepicker Calendar <3.77 is affected by cross-site scripting (XSS) in calendar_form.php. Attackers can read authentication cookies that are still active, which can be used to perform further attacks such as reading browser history, directory listings, and file contents. | Unknown | N/A | n/a | |
CVE-2021-27332 | Cross-site scripting (XSS) vulnerability in SourceCodester CASAP Automated Enrollment System v 1.0 allows remote attackers to inject arbitrary web script or HTML via the class_name parameter to update_class.php. | Unknown | N/A | n/a | |
CVE-2021-27335 | KollectApps before 4.8.16c is affected by insecure Java deserialization, leading to Remote Code Execution via a ysoserial.payloads.CommonsCollections parameter. | Unknown | N/A | n/a | |
CVE-2021-27338 | Faraday Edge before 3.7 allows XSS via the network/create/ page and its network name parameter. | Unknown | N/A | n/a | |
CVE-2021-27340 | OpenSIS Community Edition version <= 7.6 is affected by a reflected XSS vulnerability in EmailCheck.php via the "opt" parameter. | Unknown | N/A | n/a | |
CVE-2021-27341 | OpenSIS Community Edition version <= 7.6 is affected by a local file inclusion vulnerability in DownloadWindow.php via the "filename" parameter. | Unknown | N/A | n/a | |
CVE-2021-27342 | An authentication brute-force protection mechanism bypass in telnetd in D-Link Router model DIR-842 firmware version 3.0.2 allows a remote attacker to circumvent the anti-brute-force cool-down delay period via a timing-based side-channel attack | Unknown | N/A | n/a | |
CVE-2021-27343 | SerenityOS Unspecified is affected by: Buffer Overflow. The impact is: obtain sensitive information (context-dependent). The component is: /Userland/Libraries/LibCrypto/ASN1/DER.h Crypto::der_decode_sequence() function. The attack vector is: Parsing RSA Key ASN.1. | Unknown | N/A | n/a | |
CVE-2021-27345 | A null pointer dereference was discovered in ucompthread in stream.c in Irzip 0.631 which allows attackers to cause a denial of service (DOS) via a crafted compressed file. | Unknown | N/A | n/a | |
CVE-2021-27347 | Use after free in lzma_decompress_buf function in stream.c in Irzip 0.631 allows attackers to cause Denial of Service (DoS) via a crafted compressed file. | Unknown | N/A | n/a | |
CVE-2021-27349 | Advanced Order Export before 3.1.8 for WooCommerce allows XSS, a different vulnerability than CVE-2020-11727. | Unknown | N/A | n/a | |
CVE-2021-27351 | The Terminate Session feature in the Telegram application through 7.2.1 for Android, and through 2.4.7 for Windows and UNIX, fails to invalidate a recently active session. | Unknown | N/A | n/a | |
CVE-2021-27352 | An open redirect vulnerability in Ilch CMS version 2.1.42 allows attackers to redirect users to an attacker's site after a successful login. | Unknown | N/A | n/a | |
CVE-2021-27357 | RIOT-OS 2020.01 contains a buffer overflow vulnerability in /sys/net/gnrc/routing/rpl/gnrc_rpl_control_messages.c. | Unknown | N/A | n/a | |
CVE-2021-27358 | The snapshot feature in Grafana 6.7.3 through 7.4.1 can allow an unauthenticated remote attackers to trigger a Denial of Service via a remote API call if a commonly used configuration is set. | Unknown | N/A | n/a | |
CVE-2021-27362 | The WPG plugin before 3.1.0.0 for IrfanView 4.57 has a Read Access Violation on Control Flow starting at WPG!ReadWPG_W+0x0000000000000133, which might allow remote attackers to execute arbitrary code. | Unknown | N/A | n/a | |
CVE-2021-27363 | An issue was discovered in the Linux kernel through 5.11.3. A kernel pointer leak can be used to determine the address of the iscsi_transport structure. When an iSCSI transport is registered with the iSCSI subsystem, the transport's handle is available to unprivileged users via the sysfs file system, at /sys/class/iscsi_transport/$TRANSPORT_NAME/handle. When read, the show_transport_handle function (in drivers/scsi/scsi_transport_iscsi.c) is called, which leaks the handle. This handle is actually the pointer to an iscsi_transport struct in the kernel module's global variables. | Unknown | N/A | n/a | |
CVE-2021-27364 | An issue was discovered in the Linux kernel through 5.11.3. drivers/scsi/scsi_transport_iscsi.c is adversely affected by the ability of an unprivileged user to craft Netlink messages. | Unknown | N/A | n/a | |
CVE-2021-27365 | An issue was discovered in the Linux kernel through 5.11.3. Certain iSCSI data structures do not have appropriate length constraints or checks, and can exceed the PAGE_SIZE value. An unprivileged user can send a Netlink message that is associated with iSCSI, and has a length up to the maximum length of a Netlink message. | Unknown | N/A | n/a | |
CVE-2021-27367 | Controller/Backend/FileEditController.php and Controller/Backend/FilemanagerController.php in Bolt before 4.1.13 allow Directory Traversal. | Unknown | N/A | n/a | |
CVE-2021-27368 | The Contact page in Monica 2.19.1 allows stored XSS via the First Name field. | Unknown | N/A | n/a | |
CVE-2021-27369 | The Contact page in Monica 2.19.1 allows stored XSS via the Middle Name field. | Unknown | N/A | n/a | |
CVE-2021-27370 | The Contact page in Monica 2.19.1 allows stored XSS via the Last Name field. | Unknown | N/A | n/a | |
CVE-2021-27371 | The Contact page in Monica 2.19.1 allows stored XSS via the Description field. | Unknown | N/A | n/a | |
CVE-2021-27372 | Realtek xPON RTL9601D SDK 1.9 stores passwords in plaintext which may allow attackers to possibly gain access to the device with root permissions via the build-in network monitoring tool and execute arbitrary commands. | Unknown | N/A | n/a | |
CVE-2021-27374 | VertiGIS WebOffice 10.7 SP1 before patch20210202 and 10.8 SP1 before patch20210207 allows attackers to achieve "Zugriff auf Inhalte der WebOffice Applikation." | Unknown | N/A | n/a | |
CVE-2021-27375 | Traefik before 2.4.5 allows the loading of IFRAME elements from other domains. | Unknown | N/A | n/a | |
CVE-2021-27376 | An issue was discovered in the nb-connect crate before 1.0.3 for Rust. It may have invalid memory access for certain versions of the standard library because it relies on a direct cast of std::net::SocketAddrV4 and std::net::SocketAddrV6 data structures. | Unknown | N/A | n/a | |
CVE-2021-27377 | An issue was discovered in the yottadb crate before 1.2.0 for Rust. For some memory-allocation patterns, ydb_subscript_next_st and ydb_subscript_prev_st have a use-after-free. | Unknown | N/A | n/a | |
CVE-2021-27378 | An issue was discovered in the rand_core crate before 0.6.2 for Rust. Because read_u32_into and read_u64_into mishandle certain buffer-length checks, a random number generator may be seeded with too little data. | Unknown | N/A | n/a | |
CVE-2021-27379 | An issue was discovered in Xen through 4.11.x, allowing x86 Intel HVM guest OS users to achieve unintended read/write DMA access, and possibly cause a denial of service (host OS crash) or gain privileges. This occurs because a backport missed a flush, and thus IOMMU updates were not always correct. NOTE: this issue exists because of an incomplete fix for CVE-2020-15565. | Unknown | N/A | n/a | |
CVE-2021-27380 | A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532) | Unknown | N/A | Siemens | |
CVE-2021-27381 | A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534) | Unknown | N/A | Siemens | |
CVE-2021-27382 | A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040) | Unknown | N/A | Siemens | |
CVE-2021-27383 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. | Unknown | N/A | Siemens | |
CVE-2021-27384 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. | Unknown | N/A | Siemens | |
CVE-2021-27385 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. | Unknown | N/A | Siemens | |
CVE-2021-27386 | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. | Unknown | N/A | Siemens | |
CVE-2021-27387 | A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27399. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12819) | Unknown | N/A | Siemens | |
CVE-2021-27388 | SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions). | Unknown | N/A | n/a | |
CVE-2021-27389 | A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection. | Unknown | N/A | Siemens | |
CVE-2021-27390 | A vulnerability has been identified in JT2Go (All versions < V13.1.0.3), Teamcenter Visualization (All versions < V13.1.0.3). The TIFF_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13131) | Unknown | N/A | Siemens | |
CVE-2021-27391 | A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges. | Unknown | N/A | Siemens | |
CVE-2021-27392 | A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server. | Unknown | N/A | Siemens | |
CVE-2021-27393 | A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2013.08), Nucleus Source Code (Versions including affected DNS modules). The DNS client does not properly randomize UDP port numbers of DNS requests. That could allow an attacker to poison the DNS cache or spoof DNS resolving. | Unknown | N/A | Siemens | |
CVE-2021-27394 | A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges. | Unknown | N/A | Siemens | |
CVE-2021-27395 | A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data. | Unknown | N/A | Siemens | |
CVE-2021-27396 | A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279) | Unknown | N/A | Siemens | |
CVE-2021-27397 | A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287) | Unknown | N/A | Siemens | |
CVE-2021-27398 | A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290) | Unknown | N/A | Siemens | |
CVE-2021-27399 | A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820) | Unknown | N/A | Siemens | |
CVE-2021-27400 | HashiCorp Vault and Vault Enterprise Cassandra integrations (storage backend and database secrets engine plugin) did not validate TLS certificates when connecting to Cassandra clusters. Fixed in 1.6.4 and 1.7.1 | Unknown | N/A | n/a | |
CVE-2021-27401 | The Join Meeting page of Mitel MiCollab Web Client before 9.2 FP2 could allow an attacker to access (view and modify) user data by executing arbitrary code due to insufficient input validation, aka Cross-Site Scripting (XSS). | Unknown | N/A | n/a | |
CVE-2021-27402 | The SAS Admin portal of Mitel MiCollab before 9.2 FP2 could allow an unauthenticated attacker to access (view and modify) user data by injecting arbitrary directory paths due to improper URL validation, aka Directory Traversal. | Unknown | N/A | n/a | |
CVE-2021-27403 | Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow cgi-bin/te_acceso_router.cgi curWebPage XSS. | Unknown | N/A | n/a | |
CVE-2021-27404 | Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow injection of a Host HTTP header. | Unknown | N/A | n/a | |
CVE-2021-27405 | A ReDoS (regular expression denial of service) flaw was found in the @progfay/scrapbox-parser package before 6.0.3 for Node.js. | Unknown | N/A | n/a | |
CVE-2021-27406 | An attacker can take leverage on PerFact OpenVPN-Client versions 1.4.1.0 and prior to send the config command from any application running on the local host machine to force the back-end server into initializing a new open-VPN instance with arbitrary open-VPN configuration. This could result in the attacker achieving execution with privileges of a SYSTEM user. | Unknown | N/A | PerFact | |
CVE-2021-27408 | The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). | Unknown | N/A | n/a | |
CVE-2021-27410 | The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00). | Unknown | N/A | n/a | |
CVE-2021-27411 | Micrium OS Versions 5.10.1 and prior are vulnerable to integer wrap-around in functions Mem_DynPoolCreate, Mem_DynPoolCreateHW and Mem_PoolCreate. This unverified memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as very small blocks of memory being allocated instead of very large ones. | Unknown | N/A | Micrium | |
CVE-2021-27412 | Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. | Unknown | N/A | n/a | |
CVE-2021-27413 | Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. | Unknown | N/A | n/a | |
CVE-2021-27414 | An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials. | Unknown | N/A | Hitachi ABB Power Grids | |
CVE-2021-27416 | An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tricking a user to click on a link containing malicious code that would then be run by the web browser. This can result in the compromise of confidential information, or even the takeover of the user’s session. | Unknown | N/A | Hitachi ABB Power Grids | |
CVE-2021-27417 | eCosCentric eCosPro RTOS Versions 2.0.1 through 4.5.3 are vulnerable to integer wraparound in function calloc (an implementation of malloc). The unverified memory assignment can lead to arbitrary memory allocation, resulting in a heap-based buffer overflow. | Unknown | N/A | eCosCentric | |
CVE-2021-27418 | GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings. | Unknown | N/A | GE | |
CVE-2021-27419 | uClibc-ng versions prior to 1.0.37 are vulnerable to integer wrap-around in functions malloc-simple. This improper memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or a remote code injection/execution. | Unknown | N/A | uClibc-ng | |
CVE-2021-27420 | GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels. | Unknown | N/A | GE | |
CVE-2021-27421 | NXP MCUXpresso SDK versions prior to 2.8.2 are vulnerable to integer overflow in SDK_Malloc function, which could allow to access memory locations outside the bounds of a specified array, leading to unexpected behavior such segmentation fault when assigning a particular block of memory from the heap via malloc. | Unknown | N/A | NXP | |
CVE-2021-27422 | GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication. | Unknown | N/A | GE | |
CVE-2021-27424 | GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information. | Unknown | N/A | GE | |
CVE-2021-27425 | Cesanta Software Mongoose-OS v2.17.0 is vulnerable to integer wrap-around in function mm_malloc. This improper memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or a remote code injection/execution. | Unknown | N/A | Cesanta Software | |
CVE-2021-27426 | GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user. | Unknown | N/A | GE | |
CVE-2021-27427 | RIOT OS version 2020.01.1 is vulnerable to integer wrap-around in its implementation of calloc function, which can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or a remote code injection/execution. | Unknown | N/A | RIOT OS | |
CVE-2021-27428 | GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10. | Unknown | N/A | GE | |
CVE-2021-27429 | Texas Instruments TI-RTOS returns a valid pointer to a small buffer on extremely large values. This can trigger an integer overflow vulnerability in 'HeapTrack_alloc' and result in code execution. | Unknown | N/A | Texas Instruments | |
CVE-2021-27430 | GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR. | Unknown | N/A | GE | |
CVE-2021-27431 | ARM CMSIS RTOS2 versions prior to 2.1.3 are vulnerable to integer wrap-around inosRtxMemoryAlloc (local malloc equivalent) function, which can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or injected code execution. | Unknown | N/A | ARM | |
CVE-2021-27432 | OPC Foundation UA .NET Standard versions prior to 1.4.365.48 and OPC UA .NET Legacy are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow. | Unknown | N/A | n/a | |
CVE-2021-27433 | ARM mbed-ualloc memory library version 1.3.0 is vulnerable to integer wrap-around in function mbed_krbs, which can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or a remote code injection/execution. | Unknown | N/A | ARM | |
CVE-2021-27434 | Products with Unified Automation .NET based OPC UA Client/Server SDK Bundle: Versions V3.0.7 and prior (.NET 4.5, 4.0, and 3.5 Framework versions only) are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow. | Unknown | N/A | n/a | |
CVE-2021-27435 | ARM mbed product Version 6.3.0 is vulnerable to integer wrap-around in malloc_wrapper function, which can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or a remote code injection/execution. | Unknown | N/A | ARM | |
CVE-2021-27436 | WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions. | Unknown | N/A | n/a | |
CVE-2021-27437 | The affected product allows attackers to obtain sensitive information from the WISE-PaaS dashboard. The system contains a hard-coded administrator username and password that can be used to query Grafana APIs. Authentication is not required for exploitation on the WISE-PaaS/RMM (versions prior to 9.0.1). | Unknown | N/A | n/a | |
CVE-2021-27438 | The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1). | Unknown | N/A | n/a | |
CVE-2021-27439 | TencentOS-tiny version 3.1.0 is vulnerable to integer wrap-around in function 'tos_mmheap_alloc incorrect calculation of effective memory allocation size. This improper memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as a crash or a remote code injection/execution. | Unknown | N/A | TencentOS-tiny | |
CVE-2021-27440 | The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1). | Unknown | N/A | n/a | |
CVE-2021-27442 | The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code. | Unknown | N/A | Weintek | |
CVE-2021-27444 | The Weintek cMT product line is vulnerable to various improper access controls, which may allow an unauthenticated attacker to remotely access and download sensitive information and perform administrative actions on behalf of a legitimate administrator. | Unknown | N/A | Weintek | |
CVE-2021-27445 | Mesa Labs AmegaView Versions 3.0 and prior has insecure file permissions that could be exploited to escalate privileges on the device. | Unknown | N/A | Mesa Labs | |
CVE-2021-27446 | The Weintek cMT product line is vulnerable to code injection, which may allow an unauthenticated remote attacker to execute commands with root privileges on the operation system. | Unknown | N/A | Weintek | |
CVE-2021-27447 | Mesa Labs AmegaView version 3.0 is vulnerable to a command injection, which may allow an attacker to remotely execute arbitrary code. | Unknown | N/A | Mesa Labs | |
CVE-2021-27448 | A miscommunication in the file system allows adversaries with access to the MU320E to escalate privileges on the MU320E (all firmware versions prior to v04A00.1). | Unknown | N/A | n/a | |
CVE-2021-27449 | Mesa Labs AmegaView Versions 3.0 and prior has a command injection vulnerability that can be exploited to execute commands in the web server. | Unknown | N/A | Mesa Labs | |
CVE-2021-27450 | SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1). | Unknown | N/A | n/a | |
CVE-2021-27451 | Mesa Labs AmegaView Versions 3.0 and prior’s passcode is generated by an easily reversible algorithm, which may allow an attacker to gain access to the device. | Unknown | N/A | Mesa Labs |
vunerability-insight.com © 2023 - 2025. All Rights Reserved.